beautypg.com

Conexant, Ste= - set telephony extension – Comtrol AT Command Set Rev A User Manual

Page 71

background image

AT Commands Reference Manual

100722B

Conexant

3-45

–STE= - Set Telephony Extension

The –STE command enables/disables Line-In-Use, Extension Pickup, and Remote
Hangup detection features.

Note: Additional hardware may be required to support these features.

Syntax

-STE=

Defined Values

Decimal number corresponding to the selected bit-mapped
options. The bit fields are defined as follows:

Bit 0

Line-In-Use detection enable/disable.

Bit 1

Extension Pickup detection enable/disable.

Bit 2

Remote Hangup detection enable/disable.

(Dec.)

Remote
Hangup

Extension

Pickup

Line-In-Use

0 (default)

Disabled

Disabled

Disabled

1

Disabled

Disabled

Enabled

2

Disabled

Enabled

Disabled

3

Disabled

Enabled

Enabled

4

Enabled

Disabled

Disabled

5

Enabled

Disabled

Enabled

6

Enabled

Enabled

Disabled

7

Enabled

Enabled

Enabled

Reporting Current or Selected Values

Command: -STE?

Response:

-STE:

Example:

-STE: 4

Remote Hangup enabled, Extension
Pickup disabled, and Line-In-Use
disabled.

Reporting Supported Range of Parameter Values

Command: -STE=?

Show available options.

Response:

-STE: 0-7

Result Codes

OK

= 0-7

ERROR

Otherwise.

Behavior in Data Mode (+FCLASS=0)

When on-hook, if the line is in use and an ATDT is issued, the modem will not go off-
hook and will return with the message LINE-IN-USE.