Conexant, Ste= - set telephony extension – Comtrol AT Command Set Rev A User Manual
Page 71

AT Commands Reference Manual
100722B
Conexant
3-45
–STE= - Set Telephony Extension
The –STE command enables/disables Line-In-Use, Extension Pickup, and Remote
Hangup detection features.
Note: Additional hardware may be required to support these features.
Syntax
-STE=
Defined Values
Decimal number corresponding to the selected bit-mapped
options. The bit fields are defined as follows:
Bit 0
Line-In-Use detection enable/disable.
Bit 1
Extension Pickup detection enable/disable.
Bit 2
Remote Hangup detection enable/disable.
(Dec.)
Remote
Hangup
Extension
Pickup
Line-In-Use
0 (default)
Disabled
Disabled
Disabled
1
Disabled
Disabled
Enabled
2
Disabled
Enabled
Disabled
3
Disabled
Enabled
Enabled
4
Enabled
Disabled
Disabled
5
Enabled
Disabled
Enabled
6
Enabled
Enabled
Disabled
7
Enabled
Enabled
Enabled
Reporting Current or Selected Values
Command: -STE?
Response:
-STE:
Example:
-STE: 4
Remote Hangup enabled, Extension
Pickup disabled, and Line-In-Use
disabled.
Reporting Supported Range of Parameter Values
Command: -STE=?
Show available options.
Response:
-STE: 0-7
Result Codes
OK
ERROR
Otherwise.
Behavior in Data Mode (+FCLASS=0)
When on-hook, if the line is in use and an ATDT is issued, the modem will not go off-
hook and will return with the message LINE-IN-USE.