beautypg.com

Comtrol AT Command Set Rev A User Manual

Page 33

background image

AT Commands Reference Manual

100722B

Conexant

3-7

4

Reports OEM defined identifier string in either
Hayes-compatible binary format (default) or
ASCII format (selectable by ConfigurACE), e.g.:

a007040284C6002F

bC60000000
r1005111151012000
3000111170000000

5

Reports Country Code parameter (see +GCI).

6

Reports modem data pump model and internal
code revision. Example:
“RCV56DPF-PLL L8773A Rev 14.00/34.00”.

7

Reports “OK”.

Result Codes

OK

= 0 - 7.

ERROR

Otherwise.

+GMI - Request Manufacturer Identification

This command causes the modem to report the modem product manufacturer.

Syntax

+GMI

Typical Response

+GMI: CONEXANT
OK

+GMI9 - Request Conexant Identification

This command causes the modem to report CONEXANT ACF identification. The
response cannot be modified using ConfigurACE.

Syntax

+GMI9

Response

+GMI9: CONEXANT ACF
OK