Comtrol AT Command Set Rev A User Manual
Page 160

AT Commands Reference Manual
Conexant
100722B
4-10
Reporting Current or Selected Values
Command: +FTM?
Response:
+FTM:
Example:
+FTM: 98
For V.17 9600 bps.
Reporting Supported Range of Parameter Values
Command: +FTM=?
Response:
+FTM: (
Example:
+FTM: 3,24,48,72,73,74,96,97,98,121,122,145,146
+FRM - Receive Facsimile
This command causes the modem to enter the receiver mode using the modulation
defined below.
Syntax
+FRM=
Defined Values
Decimal number corresponding to the selected modulation
mode and data rates shown in Table 4-2.
Reporting Current or Selected Values
Command: +FRM?
Response:
+FRM:
Example:
+FRM: 98
For V.17 9600 bps.
Reporting Supported Range of Parameter Values
Command: +FRM=?
Response:
+FRM: (
Example:
+FRM: 3,24,48,72,73,74,96,97,98,121,122,145,146
Result Codes
CONNECT
Reported when the selected carrier is detected.
+FCERROR
Reported if another carrier is detected and FAR=0; the modem
then returns to the command state.
NO CARRIER
Reported if loss-of-carrier is detected.
OK
Reported if the DTE sends any character to the modem other
than XON or XOFF while operating in configured flow
control from the DTE; the modem then returns to the
command state.