196 - Modbus TCP Register Table
RocketLinx ES8510 and ES8510-XT User Guide: 2000513 Rev. H
ModBus TCP /IP Support
System Information (cont.)
0x0010
16 words
Product Name = "ES8510"
Word 0 Hi byte = ‘E’
Word 0 Lo byte = ‘S’
Word 1 Hi byte = ‘8’
Word 1 Lo byte = ‘5’
Word 2 Hi byte = ‘1’
Word 2 Lo byte = ‘0’
Word 3 Hi byte = ‘\0’
(other words = 0)
0x0010
16 words
Product Name = "ES8510-XT"
Word 0 Hi byte = ‘E’
Word 0 Lo byte = ‘S’
Word 1 Hi byte = ‘8’
Word 1 Lo byte = ‘5’
Word 2 Hi byte = ‘1’
Word 2 Lo byte = ‘0’
Word 3 Hi byte = ‘-’
Word 3 Lo byte = ‘X’
Word 4 Hi byte = ‘T’
Word 4 Lo byte = ‘\0’
(other words = 0)
0x0020
128 words
SNMP system name (string)
0x00A0
128 words
SNMP system location (string)
0x0120
128 words
SNMP system contact (string)
0x01A0
32 words
SNMP system OID (string)
0x01C0
2 words
System uptime (unsigned long)
0x01C2 to 0x01FF
60 words
Reserved address space
0x0200
2 words
Hardware version
0x0202
2 words
S/N information
0x0204
2 words
CPLD version
0x0206
2 words
Bootloader version
0x0208
2 words
Firmware Version
Word 0 Hi byte = major
Word 0 Lo byte = minor
Word 1 Hi byte = reserved
Word 1 Lo byte = reserved
Word Address
Data Type
Description