Comtrol ES8510-XT User Manual
Page 127

RocketLinx ES8510 and ES8510-XT User Guide: 2000513 Rev. H
Using the Serial Console - 127
Configuration Using the Command Line Interface (CLI)
•
HyperTerminal (Windows XP, unless installed manually)
-
Windows XP: Go to Start -> Program -> Accessories -> Communications -> HyperTerminal
-
Enter a name for the new console connection and click OK.
-
Enter the IP address in the Host Address text box.
-
Select TCP/IP (Winsock) in the Connect using drop-list and click Ok.
-
Set the serial settings using the
table (above).
-
Press the Enter key in the Terminal window.
-
After it is connected, you can see the Switch login request, go to
3.
Log in to the switch. The default user name is admin, password, admin.
4.
If necessary, configure the IP address for your network. The following example shows how to program an
IP address of 192.168.11.252 with a Class B subnet mask (255.255.0.0).
Switch login: admin
Password:
Switch (version 2.4a-20110930-09:49:48).
Switch>
Switch> enable
Switch# configure terminal
Switch(config)# int vlan1
Switch(config-if)# ip address 192.168.11.252/16