Troubleshooting and technical support, Troubleshooting checklist – Comtrol UP DeviceMaster Installation User Manual
Page 81
Hardware Installation and Configuration Guide: 2000451 Rev. J
Troubleshooting and Technical Support - 81
Troubleshooting and Technical Support
This section contains troubleshooting information for your DeviceMaster UP. You
may want to review the following subsections before calling Technical Support
because they will request that you perform many of the procedures or verifications
before they will be able to help you diagnose a problem.
•
•
•
Daisy-Chaining DeviceMaster UP 2E/4-Port Units
•
If you cannot diagnose the problem, you can contact
Troubleshooting Checklist
The following checklist may help you diagnose your problem:
•
Verify that you are using the correct types of cables on the correct connectors
and that all cables are connected securely.
Note:Most customer problems reported to Comtrol Technical Support
are eventually traced to cabling or network problems.
•
Verify that the network IP address, subnet mask, and gateway is correct and
appropriate for the network. Make sure that the IP address programmed into
the DeviceMaster UP matches the unique reserved IP configured address
assigned by the system administrator.
-
If IP addressing is being used, the system should be able to ping the
DeviceMaster UP.
-
If using DHCP, the host system needs to provide the subnet mask and
gateway.
•
Verify that the Ethernet hub and any other network devices between the
system and the DeviceMaster UP are powered up and operating.
Model
Connected to
Ethernet
Cable
Connector Name
1-Port
Ethernet hub or NIC
Standard
10/100 ETHERNET
1-Port Embedded
Ethernet hub or NIC
Standard
RJ45 port (not
labeled)
2-Port - 1E (Single
Ethernet Port)
Ethernet hub or NIC
Standard
10/100
2-Port - 2E (Dual
Ethernet Ports)
Ethernet hub or NIC
Standard
10/100 - E1/E2
4-Port
NIC
Standard
DOWN
Ethernet hub
Standard
UP