Hardware Installation and Configuration Guide: 2000451 Rev. J
RedBoot Procedures - 67
RedBoot Procedures
Establishing a Telnet Connection
Use the following procedure to telnet to the DeviceMaster UP.
1.
Open a telnet session, enter the DeviceMaster UP IP address.
If using Windows, you can use PortVision DX, see
Commands in Telnet/SSH Sessions (PortVision DX)
2.
Press the Enter key if you did not program a password or type the password
and press Enter.
Note: The DeviceMaster UP does not come pre-programmed with a password.
3.
Type reset, and close the session.
4.
Open a new telnet session, enter the DeviceMaster UP IP address, and the
password.
5.
Type dis to disable the Bootloader.
6.
Verify that the system responds with a Loading disabled message.
♥♦
Password:
Comtrol DeviceMaster RTS Model ID: 5002111
SocketServer 9.35
Built: Fri May 09 09:48:40 CST 2014
IP Addr: 192.168.11.23, Mask: 255.255.0.0, Gateway: 192.168.0.254
MAC Addr: 00:c0:4e:07:ff:fc
dm> reset
*********************************************
**
** Comtrol DeviceMaster Bootloader Version 3.36
** RedBoot(tm) environment - built 07:24:15, Jan 8 2014
** Platform: Comtrol DeviceMaster (ARM 7TDMI)
** Portions Copyright (C) 2000. Red Hat, Inc.
** Portions Copyright (C) 2001-2013 Comtrol Corp.
*********************************************
RAM: 0x00000000-0x007c0000 (0x00000000 - 0x07b00000 available)
FLASH: 0x05000000 - 0x053fffff, 64 x 0x10000 blocks
RedBoot> dis
Loading disabled
RedBoot> _