beautypg.com

Managing the devicemaster up, Rebooting the devicemaster up – Comtrol UP DeviceMaster Installation User Manual

Page 53

background image

Hardware Installation and Configuration Guide: 2000451 Rev. J

Managing the DeviceMaster UP - 53

Managing the DeviceMaster UP

This section discusses the following DeviceMaster UP maintenance procedures:

Rebooting the DeviceMaster UP

Uploading Firmware to Multiple DeviceMaster UPs

on Page 54

Configuring Multiple DeviceMaster UPs Network Addresses

on Page 55

Note: You can configure the network addresses for multiple DeviceMaster

UPs, configure common settings for the DeviceMaster UPs, and save the
settings to a configuration file that you can use to load settings up to all
or selected DeviceMaster UPs.

Adding a New Device in PortVision DX

on Page 55

Using Configuration Files

on Page 57

Managing Bootloader

on Page 59, which also discusses checking the

Bootloader version and downloading the latest Bootloader

Accessing RedBoot Commands in Telnet/SSH Sessions (PortVision DX)

on

Page 62

Note: You can optionally refer to

RedBoot Procedures

on Page 65 if you want to

perform procedures at the RedBoot level.

Rebooting the DeviceMaster UP

There are many ways to reboot the DeviceMaster UP.

Method

Procedure

PortVision DX

Right-click the DeviceMaster UP or DeviceMaster UPs in the
Device List pane, click Advanced >Reboot and then Yes.

Note: If security has been enabled in the web page, you will

need to reboot the DeviceMaster UP in the web page.

Web page

Main page (Server Status): Scroll to the bottom of the page,
click Reboot and then Yes: Reboot.

Telnet

Type reset.

DeviceMaster
UP

2-Port Models

DeviceMaster UP 2-port models have a Reset/Restore switch.

If the Reset/Restore switch is depressed for less than 2
seconds, the DeviceMaster UP 2-port models reboots.

If the Reset/Restore switch is depressed for greater than
approximately 5 seconds it restores the DeviceMaster UP
to the factory default values.