Hardware Installation and Configuration Guide: 2000451 Rev. J

Hardware Installation - 15

Hardware Installation

Insert the DC positive wire into the
positive screw terminal and the DC
return wire into the return screw
terminal.

If you purchased the Comtrol power
supply (separately), the wires are
identified below:

-

Red = 5-30VDC positive

-

White = 5-30VDC return

-

Black = earth ground

If you did not purchase a power supply
from Comtrol for the DeviceMaster UP,
see

1-Port

on Page 74 for power

requirements.

Use a small flat head screw to lock the wires into place.

Verify that each wire has been tightened securely.

Plug the screw terminal power connector into the
DeviceMaster UP.

Note: Align the plug properly. The scalloped side of

the screw terminal power connector should be
aligned with the scalloped side of the power
jack on the unit.

Connect the power supply to a power source.

Go to

Step 4

to verify that the DeviceMaster UP is

functioning properly.

4.

Verify that the Status LED has completed the boot cycle
and network connection for the DeviceMaster UP is functioning properly using
the table below.

5.

Go to

Configuring the DeviceMaster UP

on Page 27 to install PortVision DX,

configure the network settings, and if necessary, upload the appropriate
protocol firmware on the DeviceMaster UP.

1-Port Enclosed LED Descriptions

Status

The amber Status LED on the device is lit, indicating you have power
and it has completed the boot cycle.

Note: The Status LED flashes while booting and it takes

approximately 15 seconds for the Bootloader to complete the
cycle.
When the Bootloader completes the cycle, the LED has a
solid, steady light that blinks approximately every 10 seconds
.

Link/Act

If the red Link/Act LED is lit, it indicates a working Ethernet
connection.

Duplex

If the red Duplex LED is lit, it indicates full-duplex activity.

100

If the red 100 LED is lit, it indicates a working 100 MB Ethernet
connection (100 MB network, only). If the LED is not lit, it indicates
a 10 MB Ethernet connection.

Note: For additional LED information, go to the

Status LED table

on Page 82.

Earth Gnd

Return

Positive

5-30VDC

+

-

Wire gauge:

AWG 12-22

Screw Terminal Power Connector