4 message communication 3-48 – KEYENCE DL-EP1 User Manual
Page 78

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IB) -
3-4 Message Communication
3-48
3
C
om
m
uni
ca
tin
g
w
ith
IB
S
er
ie
s
Group4
0394H
(916)
Ext. IN3
function
selection
*14
Sets the function to be assigned to external input 3.
Parameter range: 0 to 4 (initial value: 0)
0: Timing input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not use
R/W
DINT
0395H
(917)
Ext. IN4
function
selection
*14
Sets the function to be assigned to external input 4.
Parameter range: 0 to 4 (initial value: 4)
0: Adjust input
1: Bank A input
2: Bank B input
3: Laser emission stop input
4: Not use
R/W
DINT
0396H
(918)
Bank
switching
method
Sets the bank switching method.
Parameter range: 0 to 1 (initial value: 0)
0: Button
1: External Input
R/W
DINT
0397H
(919)
(Reserved for system)
0398H
(920)
Save zero-
shift state
Sets whether to store the zero shift status.
Parameter range: 0 to 1 (initial value: 0)
0:OFF
1:ON
R/W
DINT
0399H
(921)
(Reserved for system)
039AH
(922)
Display digit
Sets the display resolution.
When measurement mode is % mode:
0: Initial setting (dEFLt) (initial value)
1: (Reserved for system)
2: (Reserved for system)
3:0.01
4:0.1
5:1
When measurement mode is dimension mode:
0: Initial setting (dEFLt) (initial value)
1: (Reserved for system)
2:0.001
3:0.01
4:0.1
5:1
R/W
DINT
039BH
(923)
Power save
function
Sets the power saving function.
Parameter range: 0 to 2 (initial value: 0)
0:OFF
1: Half
2: All
R/W
DINT
039CH
(924)
(Reserved for system)
Class