3-4 Message Communication

3-25

3

C

om
m

uni

ca

tin

g

w

ith

IB

S

er

ie

s

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (IB) -

(5) Reading the number of decimal places from a sensor amplifier

Message communication reads the number of decimal places of settings read
from the sensor amplifier.

"(5) Reading the number of decimal places in the parameter from a sensor

amplifier" (Page 3-60)

For the IB Series, if measurement mode is "% mode" and the current value
is 12.50%, data is stored as follows:
Data: 1250
Number of decimal places: 2

Perform calculation from the read data and the number of decimal places.

IB

Command

Response

DL-EP1

Scanner


Service code: 4CH
Class ID: 67H
Instance ID: 01H
Attribute ID: 0325H(805)

Reads the number of decimal places of
the IB comparator value (P.V. value).

Reference

125012.5012.5%

Number of
decimal places

2 1