beautypg.com

Electrical specification, Supply voltage, Rtc/backup voltage – Kontron SMARC-sA3874i User Manual

Page 47: No separate standby voltage, Module i/o voltage, 5 electrical specification

background image

47

www.kontron.com

User’s Guide

3.5 Electrical Specification

3.5.1 Supply Voltage

The ULP-COM sA3874i module operates over an input voltage range of 3.1V to 5.25V. Power is provided from the
carrier through 10 power pins as defined by the ULP-COM specification.

Caution!

The ULP-COM specification states that the input voltage range should extend down to 3.0V. The sA3874i

lower limit is determined by a non-volatile register setting in the TI PMU used.

3.5.2 RTC/Backup Voltage

3.0V RTC backup power is provided through the VDD_RTC pin from the carrier board. This connection provides
back- up power to the module PMU.

3.5.3 No Separate Standby Voltage

The ULP-COM sA3874i does not have a standby power rail. Standby operation is powered through the main supply
voltage rail, as defined in the ULP-COM specification.

3.5.4 Module I/O Voltage

The ULP-COM sA3874i module complies with the default I/O voltage (1.8V) level defined by ULP-COM Hardware
specification. Module pin S158 (VDD_IO_SEL#) is tied low on the Module, per the ULP-COM specification,
indicating a 1.8V I/O voltage level.