beautypg.com

Power button (pwrbtn#), Reset button (sys_reset#), Power supply – Kontron COMe-cXLi2 User Manual

Page 47: Single supply mode, Table 11: single supply mode

background image

Kontron COMe-cXLi2 User’s Guide

www.kontron.com

41

Specification. PWR_OK is internally pulled up to 3.3V and must be high-level

to power on the module.

Power Button (PWRBTN#)

The power button (pin B12) is available through the module connector as

defined in the pin-out list. To start the module using the power button the

PWRBTN# signal must be at least 50ms (50ms

≤ t < 4sec) at low-level power.

By pressing the power button for at least four seconds, the module can be put

into the power-off mode.

Reset Button (SYS_RESET#)

The reset button (pin B49) is available through the module connector as

defined in the pin-out list. The module stays in reset as long as SYS_RESET#

is grounded.

Power Supply

The COMe-cXLi2 COM has a wide range of power inputs, from 5V to 18V DC. The

supply voltage is applied through 42 pins (VCC) on the module connector.

The module does not support ATX mode. The COMe-cXLi module will auto power

on whenever +5V_Standby or +12V is present without pressing the power on

button.

Single Supply Mode

Single Supply Mode:

In single supply mode the module starts automatically when VCC power is

connected and Power Good input is open or at high-level (internal PU to

3.3V). PS_ON# is not used in single supply mode.

To power on the module from the S5 state, press the power button or reconnect

VCC.

Table 11: Single Supply Mode

State

PWRBTN#

PWR_OK

V5_StdBy

VCC

G3

X

x

x

0

G3 -> S0

High

open / high

x

connecting

VCC

S5

high

open / high

x

VCC