Preventative maintenance, Things to check – Dynojet 424xLC2: Installation Guide User Manual
Page 138

C H A P T E R 6
Preventative Maintenance
Above Ground Model 424x/424xLC
2
Automotive Dynamometer Installation Guide
6-12
PREVENTATIVE MAINTENANCE
This section covers maintenance items for all model 424 dynos with the Spring
Applied Air Release (SAAR) brake and the 4WD attachment. For more detailed
maintenance instructions, refer to the Maintenance Guide for Automotive
Dynamometers (P/N 98119101).
T
HINGS
TO
C
HECK
• Check all air fittings for leaks monthly. Correct any leaks found.
• Once per month verify the brake pressure gauge reads 100psi (690kPa). Adjust the
regulator if the pressure is out of specification. Refer to page 6-13 for more
information.
• Check the brake shoe clearance. Refer to page 6-14 for more information.
• Dyno Bearing Grease:
Under steady use, over 25 runs per day, each bearing should receive .65oz (19 ml)
of a recommended grease every 2 months.
Under occasional use, less than 25 runs per day, each bearing should receive .65oz
(19 ml) of a recommended grease every six months.
Recommended Grease:
grease specification
description
thickener
Lithium 12 Hydroxy Stearate
oil
Petroleum
thickness
NLGI 2
operating temperature
-29°C to 93°C, intermittent to 121°C
(-20°F to 200°F, intermittent to
250°F)
EP additive
yes
examples
Mobil Mobilith AW-2