Load cell calibration – Dynojet 424xLC2: Installation Guide User Manual
Page 115

4-19
E D D Y C U R R E N T B R A K E I N S T A L L A T I O N
Load Cell Calibration
Version 1
Above Ground Model 424x/424xLC
2
Automotive Dynamometer Installation Guide
LOAD CELL CALIBRATION
Before proceeding, make sure all cables have been routed and the covers have been
installed.
This section provides instructions for calibrating the load cell. Follow the directions on
the screen exactly. Failure to perform the directions accurately will result in improper
torque values.
You will need the following parts:
• 35430899
Weight (4)
• 61319001
Calibration Arm Assembly
1
Double-click the Power Core program icon.
2
Click Dyno Control from the Application Launcher.
3
Verify you are connected to the dyno electronics.
Note: For more information on connecting to the dyno electronics, refer to the
Power Core Quick Start Guide (on your Power Core CD or at www.dynojet.com) or
the Power Core Online Help.
4
Click the Configuration tab.
5
Click Load Cell Calibration.
The Calibration Window will appear.
Note: Before proceeding, be sure the eddy current brake is free and clear of any
obstructions. There should not be anything resting on the eddy current brake or
the dynamometer drum during this procedure.
6
Click Next to zero the load cell.
The hardware is now zeroing out the torque cell.
Figure 4-19: Zero Calibration Window