Installing and Configuring Hardware

59

Perform the following steps to configure the hardware to utilize
redundantpaths on the PERC 6/E adapter:

1 Set up an enclosure on the PERC 6/E adapter.
2 Connect two SAS cables from the OUT ports on your PERC 6/E adapter

to the IN ports of the external enclosure. See Figure 4-3 to view the
connection of the cables from the external enclosure to the PERC 6/E
adapter.

NOTE:

For information on Unified Mode, see the enclosure documentation

that was shipped with the system.

3 To add multiple enclosures, cable both OUT ports of the first enclosure

to both IN ports of the next enclosure.

After you set up the hardware, the controller detects the redundant paths and
automatically utilizes them to balance the I/O load.

Removing and Installing the CERC 6/i Modular
Storage Controller Card (Service-Only Procedure)

The Modular Storage Controller Card is located below the hard drive bays of
the Dell Modular

Blade system. To remove the Modular Storage Controller Card:

1 Remove the Dell Modular Blade system from the Modular blade system

chassis. For more information on removing the blade system from the
Modular Blade system chassis, see your system’s Hardware Owner’s
Manual or the User’s Guide.

2 Remove the system cover of the Modular blade system. For more

information on opening the top cover of the Modular blade system, see
your system’s Hardware Owner’s Manual or the User’s Guide.

3 Remove the system board and place it on a stable, flat work surface.

For more information on removing the system board, see your system’s
Hardware Owner’s Manual or the User’s Guide.