Dell PowerEdge RAID Controller 6i User Manual
Page 89
Configuring and Managing RAID
89
If you attempt to run a Consistency Check on a virtual disk that has not been
initialized, the following error message displays:
The virtual disk has not been initialized. Running a
consistency check may result in inconsistent messages
in the log. Are you sure you want to continue?
You can select Yes or No. If you select Yes, the CC operation continues.
If you select No, the operation ends.
Perform the following steps to run a Consistency Check.
1 Press
2 Press the down arrow key to highlight Virtual Disk #.
3 Press
4 Press the down arrow key to select Consistency Check.
5 Press the right arrow key to display the menu of available actions, Start
and Stop.
6 Select Start and press
The Consistency Check runs and checks the redundancy data in the
virtual disks.
7 After you start the Consistency Check, press
previous menu.
Importing or Clearing Foreign Configurations Using the VD Mgmt Menu
When a foreign configuration exists, the BIOS banner displays the message
Foreign configuration(s) found on adapter
. In addition,
a foreign configuration, when present, appears on the right side of the
VD Mgmt screen.
You can use the VD Mgmt menu to import the existing configuration to the
RAID controller or clear the existing configuration to create a new one. In
addition, you can view the foreign drive data from the Foreign View tab
without importing the configuration.
NOTE:
The controller does not allow an import that results in more than 64 virtual
disks.
Dell_PERC6.1_UG.book Page 89 Wednesday, April 15, 2009 4:18 PM