beautypg.com

Smart errors – Dell PowerEdge RAID Controller 6i User Manual

Page 123

background image

Troubleshooting

123

SMART Errors

Table 7-6 describes issues related to the Self-Monitoring Analysis and Reporting
Technology (SMART). SMART monitors the internal performance of all
motors, heads, and physical disk electronics and detects predictable physical
disk failures.

NOTE:

For information about where to find reports of SMART errors that could

indicate hardware failure, see the Dell OpenManage Storage Management
documentation.

Table 7-6.

SMART Errors

Problem

Suggested Solution

A SMART error is
detected on a physical
disk in a redundant
virtual disk.

Perform the following steps:

1

Force the physical disk offline.

NOTE:

If a hot spare is present, the rebuild starts with the hot

spare after the drive is forced offline.

2

Replace it with a new physical disk of equal or higher
capacity.

3

Perform the Replace Member operation.

The Replace Member operation allows you to copy data
from a source physical disk of a virtual disk to a target
physical disk that is not a part of the virtual disk. See "Using
the SMART Feature" on page 24 for mor
e information
about the

Replace Member feature.

A SMART error is
detected on a physical
disk in a
non-redundant virtual
disk.

Perform the following steps:

1

Back up your data.

2

Use Replace Member or set up a global hot spare to replace
the disk automatically.

See "Replacing an Online Physical Disk" on page 106 for
information about the

Replace Member feature.

3

Replace the affected physical disk with a new physical disk
of equal or higher capacity.

4

Restore from the backup.

Dell_PERC6.1_UG.book Page 123 Wednesday, April 15, 2009 4:18 PM