Dell PowerEdge RAID Controller 6i User Manual
Page 116
116
Troubleshooting
Physical disk removed:
Physical Disk {x.x.x}
Controller {x}, Connector
{x}
Device failed: Physical
Disk {x.x.x} Controller
{x}, Connector {x}".
These two messages appear in the event log
when you remove a drive. The first message
indicates that the disk was removed and the
second message indicates that the device has
failed. This feature is working as designed.
A storage component such as a physical disk or
an enclosure has failed. The failed component
might have been identified by the controller
while performing a task such as a rescan or a
check consistency.
Replace the failed component. You can identify
the failed dsik as its status displays a red
X
.
Perform a rescan after replacing the disk.
Battery is missing or the
battery could be fully
discharged. If battery is
connected and has been
allowed to charge for 30
minutes and this message
continues to appear, then
contact Technical Support
for assistance.
• The controller battery is missing or damaged.
• The controller battery is completely
discharged and needs to be charged for it to
become active. The battery must first be
charged, and then it is found by the system
several minutes later.
Table 7-1.
BIOS Errors and Warnings (continued)
Message
Meaning
Dell_PERC6.1_UG.book Page 116 Wednesday, April 15, 2009 4:18 PM