Controller management, Enabling boot support – Dell PowerEdge RAID Controller 6i User Manual
Page 108

108
Configuring and Managing RAID
3 Press
The Rebuild option is highlighted at the top of the menu.
4 Press the right arrow key to display the rebuild options and select Start.
5 After you start the rebuild, press
NOTE:
You can also use the VD Mgmt screen to perform a manual rebuild. Use the
arrow key to highlight physical disk in the tree view, and press
that displays, select the Rebuild option.
NOTICE:
If a physical disk is a member of a disk group that contains multiple virtual
disks and one of the virtual disks is deleted when a rebuild operation is in progress,
the rebuild operation stops. If this occurs, you can resume the rebuild operation
manually using a storage management application. To avoid interruption, ensure
that none of the virtual disks are deleted until the rebuild is complete.
Controller Management
Enabling Boot Support
NOTE:
Refer to your system documentation to ensure the proper boot order is
selected in the system BIOS.
In a multiple controller environment, you can enable BIOS on multiple
controllers. However, if you want to boot from a specific controller, then enable
the BIOS on that controller and disable it on the other controllers. The system
can then boot from the BIOS-enabled controller. Perform the following steps to
enable the controller BIOS.
1 Press
2 Press
Settings box.
3 Press the spacebar to select Enable Controller BIOS.
An X displays beside Enable Controller BIOS.
4 Press
The controller BIOS is enabled. To disable the controller BIOS, use the
spacebar to deselect the Enable Controller BIOS control, and then select
Apply and press
Dell_PERC6.1_UG.book Page 108 Wednesday, April 15, 2009 4:18 PM