Fault tolerance features, Physical disk hot swapping – Dell PowerEdge RAID Controller 6i User Manual
Page 36
36
About PERC 6 and CERC 6i Controllers
Fault Tolerance Features
Table 3-3 lists the features that provide fault tolerance to prevent data loss in
case of a failed physical disk.
Physical Disk Hot Swapping
Hot swapping is the manual substitution of a replacement unit in a disk
subsystem for a defective one. The manual substitution can be performed while
the subsystem is performing its normal functions.
NOTE:
The system backplane or enclosure must support hot swapping in order for
the PERC 6 and CERC 6/i controllers to support hot swapping.
NOTE:
Ensure that SAS drives are replaced with SAS drives, and SATA drives are
replaced with SATA drives.
NOTE:
While swapping a disk, ensure that the new disk is of equal or greater
capacity than the disk that is being replaced.
Table 3-3.
Fault Tolerance Features
Specification
PERC
CERC
Support for SMART
Yes
Yes
Support for Patrol Read
Yes
Yes
Redundant path support
Yes
N/A
Physical disk failure detection
Automatic
Automatic
Physical disk rebuild using hot spares
Automatic
Automatic
Parity generation and checking (RAID 5, 50, 6, and
60 only)
Yes
N/A
Battery backup of controller cache to protect data Yes
a
N/A
Manual learn cycle mode for battery backup
Yes
N/A
Detection of batteries with low charge after
bootup
Yes
N/A
Hot-swap manual replacement of a physical disk
without reboot
Yes
Yes
a
The PERC 6/i adapter supports a BBU on selected systems only. For additional information, see
the documentation that was shipped with the system.
Dell_PERC6.1_UG.book Page 36 Wednesday, April 15, 2009 4:18 PM