beautypg.com

Cooper Instruments & Systems DFI INFINITY Digital Force Indicator/Controller User Manual

Page 2

background image

CONTENTS

NOTES, WARNINGS AND CAUTIONS .......................................................................................1
1.0 INTRODUCTION ....................................................................................................................1

1.1 Description ......................................................................................................................................1

1.2 Features ...........................................................................................................................................1

1.3 Available Models.............................................................................................................................1

2.0 UNPACKING ..........................................................................................................................2
3.0 SAFETY CONSIDERATIONS ................................................................................................3
4.0 PARTS OF THE METER........................................................................................................4

4.1 Front Of The Meter..........................................................................................................................4

4.2 Rear Of The Meter ...........................................................................................................................6

5.0 SETUP....................................................................................................................................7

5.1 Conditions Requiring Disassembly...............................................................................................7

5.2 Assembly/Disassembly Opening...................................................................................................8

5.2.1 Safety Precaution/Product Id Label........................................................................................9

5.2.2 Main Board Power Jumpers ....................................................................................................9

5.2.3 Printed Circuit Board(s) Installation.....................................................................................10

5.2.4 How To Access Jumpers.......................................................................................................10

5.2.5 Panel Mount Assembly ..........................................................................................................13

6.0 JUMPER POSITIONS ..........................................................................................................15

6.1 Introduction ...................................................................................................................................15

6.2 S1 Jumper Positions For Readrate And Unipolar Or Bipolar Input(S).....................................15

6.3 S2 Jumper Positions For Input Ranges ......................................................................................15

6.4 Jumper Setting(s) For Sensor Excitation ...................................................................................16

6.4.1 Jumper Settings for Sensor Excitation –ac Powered Unit .................................................17

6.4.2 Jumper Settings for Sensor Excitation – dc Powered Unit................................................17

7.0 SIGNAL AND POWER INPUT CONNECTIONS..................................................................18

7.1 Introduction ...................................................................................................................................18

7.2 Signal Input Connections.............................................................................................................18

7.3 AC Wiring Connection..................................................................................................................20

8.0 METHODS FOR SCALING THE METER TO DISPLAY IN ENGINEERING UNITS............21

8.1 Introduction ...................................................................................................................................21

8.2 Setup Meter Input Type and Range .............................................................................................21

8.3 Scaling Your Meter Using 2-Coordinate Input Scale And Offset (IN.SC.OF) With Sensor
Connected To Your Meter ..................................................................................................................22

8.3.1 SETTING INPUT CONFIGURATION (IN CNF) .......................................................................23

8.3.2 Scaling Your Meter With Your Sensor Connected ..............................................................23

8.3.3 To Select Decimal Point Position (DEC PT).........................................................................24

8.3.4 Entering Zero Offset Numbers ..............................................................................................25

8.4 Scaling Your Meter Without Connecting A Sensor Using Calculated Values.........................26

8.4.1 Preparing Your Meter For Scaling With Input Scale And Offset........................................26

8.4.2 Scaling Your Meter.................................................................................................................27

8.4.3 To Select Decimal Point Position .........................................................................................29

8.4.4 Entering Zero Offset Numbers ..............................................................................................30

9.0 LOCKOUT CONFIGURATIONS AND METER FUNCTION MENUS...................................31

9.1 Individual Lockout Information....................................................................................................31

9.2 Meter Function Menus..................................................................................................................34

9.2.1 INPUT ......................................................................................................................................34

CF 67

ii

M1291/N/0403 11279ML-02 Rev. A