Seed alarm speed (shaft rate), Seed alarm delay time – Great Plains V-300F Operator Manual User Manual

Page 73

background image

Great Plains Manufacturing, Inc.

Monitor Operation

69

11/15/2007

148-057M-A

Seed Alarm Speed (Shaft Rate)

The default alarm threshold is 0 rpm (shaft stopped). If
you want an alarm at some low speed other than
stopped, change the threshold rpm as follows:

1.

Channel Select

to the Seed

channel.

2.

Press and hold the

button to enter Program

Mode 1.

The threshold rpm displays after 3 seconds.

3.

Continue holding the

button and press

to

select the digit to change.
Hold

to change the selected digit.

Release

to select the next digit, and repeat as

above.

4.

Release both buttons when done. The instrument
returns to the normal display mode.

Seed Alarm Delay Time

Some crops – notably oilseed rape (canola) are drilled at
very low rates, the seed shaft runs extremely slowly and
the instrument may incorrectly sense a stoppage.
Change the delay time to prevent nuisance alarms.

When drilling at higher rates, a long time delay is equally
undesirable. In this case program a shorter delay.

The default alarm delay is 040 seconds after the shaft
rpm drops below the threshold value (or to 0). The mini-
mum delay time is 005 seconds.

Change the delay time as follows:

1.

Power-off the console using its rear panel switch.

2.

While holding down the

button, re-apply power

to enter Program Mode 2 “CAL.2”.

3.

Press

to select the Seed

channel.

The threshold rpm displays after 3 seconds.

4.

Press

to select the digit to change.

Hold

to change the selected digit.

Release

to select the next digit, and repeat as

above.

5.

Release all buttons. Switch off and restore power to
save the selection. The instrument resumes normal
mode at next power-on.

Figure 68

Seed Shaft Alarms at 0 rpm

22632

Figure 69

Seed Alarms at 10 Sec.

22632