beautypg.com

Great Plains V-300F Operator Manual User Manual

Page 41

background image

Great Plains Manufacturing, Inc.

Operations

37

11/15/2007

148-057M-A

Refer to Figure 38
2.

With the tractor hydraulic lever locked forward,
release the lock disk

, turn the knob

on the pres-

sure control valve

.

3.

Watch the pressure gauge

and dial in the desired

pressure on the openers. Clockwise increases the
pressure and counterclockwise decreases pressure.

4.

Once the pressure is set, lock the knob with the lock
disk.

The recommended pressure range for drilling is between
200 psi and 1400 psi. Setting the opener down pressure
above 1600 psi raises the drive wheels off the ground
when the seed box is empty, causing skips and poor
seed metering. See the following table for the relation-
ship between psi and down force.

The following down-forces are per-opener, with no extra
weight on the hangers (at the lower down-force values).
Higher down-force values may require weights on the
hangers

Adjustment Valve Effect

System PSI

Down Force per Row

kg

lbs

200

62

137

300

77

170

400

84

185

500

96

212

600

110

243

700

123

272

800

139

306

900

*

*

Settings at and above 900 psi may require extra
weights.

155

341

1000*

173

380

1100*

194

427

1200*

217

479

1300*

249

548

1400*

268

591

Figure 38

Down-Pressure Adjustment

27231

4

1

2

3

1

2

3

4