Disable Fertilizer Shaft Alarm
This procedure disables the fertilizer shaft alarm for the
current planting session.
1.
Channel Select
to Fertilizer
.
2.
Push and hold the Stop/Reset
button for 5 sec-
onds. The console displays “OFF” and beeps twice,
indicating that the function is disabled.
The function remains disabled until power is lost. This is
the recommended setting for V300F drills that are not
presently applying fertilizer.
Note: There is no key sequence to re-enable fertilizer
shaft alarm during the current session. Cycle pow-
er to restore it.
To disable fertilizer alarms in a manner that is preserved
across power cycles, set the shaft rate (pulses per revo-
lution) to 0 (page 64). This is the recommended setting
for V300 drills, which have no fertilizer system (but do
have the shaft sensor lead, which would otherwise
always report 0 rpm, resulting in nuisance alarms).
Fertilizer Alarm Speed Threshold
The default alarm threshold is 0000 rpm (shaft stopped).
If you want an alarm at some low speed other than
stopped, change the threshold rpm as follows:
1.
Channel Select
to the Fertilizer
channel.
2.
Press and hold the
button to enter Program
Mode 1.
The threshold rpm displays after 3 seconds.
3.
Continue holding the
button and press
to
select the digit to change.
Hold
to change the selected digit.
Release
to select the next digit, and repeat as
above.
4.
Release both buttons when done. The instrument
returns to the normal display mode.
Figure 62
Fertilizer Alarm Temporarily Disabled
22632
Figure 63
Fertilizer Alarms at 1 rpm
22632