beautypg.com

Manual s.s.f. entry – Great Plains V-300F Operator Manual User Manual

Page 55

background image

Great Plains Manufacturing, Inc.

Monitor Operation

51

11/15/2007

148-057M-A

Manual S.S.F. Entry
For a typical V300, firm dry ground, nominal wheel slip-
page and new tires inflated to factory specification, the
calculated calibration figure is:
3.235 meters (Metric units mode) or
127.4 inches (Imperial units mode).

Note: The factory default is 2.000 (meters) or 78.78 (inch-

es), and is not correct for the V300/V300F.

To change the S.S.F:

1.

Channel Select

to Forward Speed

.

Refer to Figure 51
2.

Press and hold the

to enter Program Mode 1.

The units of measure display (see page 47) appears
for a few seconds. Continue holding the button until a
numeric display appears.

3.

While continuing to hold

, use Channel Select

to select a digit, and then the decimal point.

Continue to hold

to cycle slowly between 0-9

and decimal point positions. Release

at desired

values.

4.

While continuing to hold

, press

again to

select the next display element, and hold to change.
Repeat until the desired value is entered.

5.

Release

to save the new values.

Figure 51

Nominal S.S.F. Value (m)

22632