Tramline sequence/bout selection, Select the sequence, Select the tramline bout – Great Plains V-300F Operator Manual User Manual
Page 59: Select the sequence select the tramline bout
Great Plains Manufacturing, Inc.
Monitor Operation
55
11/15/2007
148-057M-A
Tramline Sequence/Bout Selection
1.
If tramlining has been disabled, re-enable it before
selecting the sequence. See page 56.
2.
Channel Select
to Tramline
.
Select The Sequence
Press and hold
to enter Program Mode 1.
After 3 seconds the first two characters flash, indicat-
ing the tramline sequence currently set.
4.
While continuing to hold
, hold Channel Select
to select the required sequence. Release only
the
button when the sequence is set.
Select the Tramline Bout
While continuing to hold
, press and release the
button to toggle between the tramline sequence
and tramline bout number display. The 3rd and 4th
characters flash indicating the tramline bout number
currently set.
6.
Press and hold the
button to cycle tramline the
bout from .01 to .15.
Note: Setting the bout to “.00” disables the tramline func-
tion. In normal mode, the indicator chevron may not
index to the tramline function. To re-enable tramlin-
ing, see page 56.
Note: If either asymmetric left (“AL.”) or asymmetric right
(“Ar.”) sequences are selected, the tramline out-
put is also switched on for the bout following the tar-
get bout (i.e. bout 1).
If the special asymmetric sequence (“AS.”) is se-
lected, the only options for the tramline bout num-
ber are .10, .18 and .20.
7.
Release all buttons.
SY.
SYmmetric
Bouts .01 to .15
AL.
Asymmetric Left
Bouts .01 to .15
Ar.
Asymmetric right
Bouts .01 to .15
AS.
Asymmetric Special
Bouts .10, .18, .20
Figure 54
Tramline Sequence Selection
22632
Figure 55
Tramline Bout Selection
22632