beautypg.com

Tramline sequence/bout selection, Select the sequence, Select the tramline bout – Great Plains V-300F Operator Manual User Manual

Page 59: Select the sequence select the tramline bout

background image

Great Plains Manufacturing, Inc.

Monitor Operation

55

11/15/2007

148-057M-A

Tramline Sequence/Bout Selection

1.

If tramlining has been disabled, re-enable it before
selecting the sequence. See page 56.

2.

Channel Select

to Tramline

.

Select The Sequence

Refer to Figure 54
3.

Press and hold

to enter Program Mode 1.

After 3 seconds the first two characters flash, indicat-
ing the tramline sequence currently set.

4.

While continuing to hold

, hold Channel Select

to select the required sequence. Release only

the

button when the sequence is set.

Select the Tramline Bout

Refer to Figure 55
5.

While continuing to hold

, press and release the

button to toggle between the tramline sequence

and tramline bout number display. The 3rd and 4th
characters flash indicating the tramline bout number
currently set.

6.

Press and hold the

button to cycle tramline the

bout from .01 to .15.

Note: Setting the bout to “.00” disables the tramline func-

tion. In normal mode, the indicator chevron may not
index to the tramline function. To re-enable tramlin-
ing, see page 56.

Note: If either asymmetric left (“AL.”) or asymmetric right

(“Ar.”) sequences are selected, the tramline out-
put is also switched on for the bout following the tar-
get bout (i.e. bout 1).

If the special asymmetric sequence (“AS.”) is se-
lected, the only options for the tramline bout num-
ber are .10, .18 and .20.

7.

Release all buttons.

SY.

SYmmetric

Bouts .01 to .15

AL.

Asymmetric Left

Bouts .01 to .15

Ar.

Asymmetric right

Bouts .01 to .15

AS.

Asymmetric Special

Bouts .10, .18, .20

Figure 54

Tramline Sequence Selection

22632

Figure 55

Tramline Bout Selection

22632