Monitor operation, Monitor introduction, Monitor operation monitor introduction – Great Plains V-300F Operator Manual User Manual
Page 47
11/15/2007
148-057M-A
Great Plains Manufacturing, Inc.
Monitor Operation
43
Monitor Operation
Monitor Introduction
The multi-function drill monitor controls the operation and
tramlining functions.
Refer to Figure 42 and Figure 43
The instrument
1
has:
an illuminated four-digit/six-chevron display,
six display functions (indicated by chevron),
three active control buttons.
There are alarm functions for forward speed, seed distri-
bution shaft rpm, fertilizer shaft rpm and main hopper
levels. The speed and area functions can be displayed in
either metric or imperial units. A power switch on the
back
is used primarily for certain system settings.
The instrument indicates:
• Forward Speed (plus low speed alarm)
• Part Area and Total Area worked
• The current bout number and tramline bouts for the
selected tramlining sequence.
• Fertilizer Distribution Shaft Alarm
• Seed Distribution Shaft Alarm
• Seed Hopper Level Low
• Fertilizer Hopper Level Low
The tramlining
2
function is the priority display. Unless
tramlining is disabled, the instrument defaults to this
channel display 10 seconds after selecting another dis-
play function (with the exception of displaying an area
total or when the drill is out of work).
1. These instructions are based on firmware revision A.401 E.001 r.004
Figure 42
Seed Monitor Console, Front
22632
1
2
3
Note: The monitor console can be operated with the har-
ness disconnected from the drill. Some functions,
such as Speed Sensor Calibration, are unavailable
when operated disconnected.
Figure 43
Seed Monitor Console, Back
27236
4