Air system clean-out – Great Plains YP1625 Operator Manual User Manual
Page 83

Great Plains Manufacturing, Inc.
Maintenance and Lubrication
79
03/12/2012
401-226M-A
Air System Clean-Out
Shut off slide gate door at bottom of seed box or bulk
hopper.
2.
Place a pan or tarp under the airbox manifold to
catch seed.
Refer to Figure 112
3.
Open airbox clean-out door to empty seed from the
manifold.
Note: If needed, additional access doors are provided.
4.
Shut the clean-out door under manifold.
5.
Turn on the air fan and let it run.
Refer to Figure 113
6.
If the planter has Y-tubes, shut off the gates at all of
the Y-tubes.
7.
Start at one end of planter and open the meter clean
out door for the end row-unit. Place a bucket under
the meter to catch the seed.
8.
Open the Y-tube gate feeding that meter. Let the air
blow seed out of the meter. Keep the meter open for
a couple of minutes after the seed stops blowing out.
9.
Close the Y-tube gate feeding that meter. Close the
meter clean out door.
10. Repeat procedure on the next meter in line. Continue
with this procedure until you have reached the oppo-
site end of the planter.
FigureSpacer:
Figure 111
Slide Gate Closed
29495
3
FigureSpacer:
Figure 112
Airbox Clean-Out Door Open
29494
2
FigureSpacer:
Figure 113
Y-Tube Shut-Off
22843