beautypg.com

Disengage meter – Great Plains YP1625 Operator Manual User Manual

Page 61

background image

Great Plains Manufacturing, Inc.

Adjustments

57

03/12/2012

401-226M-A

Refer to Figure 77
7.

Shut off Y-tube port for the current row unit.

Disengage Meter

Refer to Figure 78
8.

Uncouple meter drives for the locked-up rows. Pull
shaft out and park pin in shallow detents.

Machine Damage Risk:
Do not disable meters by removing them or chain drive dam-
age will occur.

9.

Repeat for all rows needing lock-up.

10. Reset marker extension (page 129).

11. Reset monitor active row pattern and row spacing to

avoid nuisance alarms.

End of “Row Unit Shut-Off

FigureSpacer:

Figure 77

Y-Tubes Open

22843

FigureSpacer:

Figure 78

Row Unit Drive Coupler

Engaged (Left) and

Disengaged (right) for Row Shut-Off

26171

This manual is related to the following products: