3.09 Optional Wire Feeder Set Up MIG (GMAW) Welding with Gas Shielded MIG Wire
The Transmig 250i is supplied with a Tweco Fusion 250 AMP air-cooled MIG Torch. The Fusion MIG Torch is designed
with an ergonomic handle and fewer parts to reduce performance problems. The Fusion MIG Torch uses standard
readily available Tweco consumable parts.
When using a Gas Shielded wire with the 2RT Wire Feeder, you need to have an external gas source attached to the 2RT.
For most Gas Shielded wire, connect the Work Lead to the negative - terminal on the front of the 250i and connect
the Welding Power Cable from the back of the 2RT to the positive + terminal on the front of the 250i. Check with wire
manufacturer for recommended polarity.
The 2RT Wire Feeder is fitted with an 8M interconnection cable assembly to connect from the back of the 2RT to the
front of the 250i welding power source.
Connect the MIG Torch to the front of the 2RT as you would to the front of the 250i in Sections 3.23 and 3.24.
+
-
Front View 2RT
Rear View 2RT
Front View 250i
Control Cable
Welding Power Cable
from Wire Feeder
Work Lead
Art # 10335
Gas Hose
Figure 3-9: Setup for 2RT Wirefeeder
WARNING
Before connecting the work clamp to the work make sure the mains power supply is switched OFF.
CAUTION
Loose welding terminal connections can cause overheating and result in the male plug being fused in the
terminal.
Remove any packaging material prior to use. DO NOT block the air vents at the front or rear of the Welding
Power Source.
NOTE
Depending on the type of wire you will be using the Welding Power Cable may need to be switched. Follow
the wire manufacturers recommendation.
NOTE
Spool hub and feed plate set up and operation are the same as the 250i which can be reviewed later in this
section starting at 3.14.