beautypg.com

Introduction transmig 250i, 09 duty cycle, Safe operating region – Tweco 250i Transmig Inverter User Manual

Page 17: With factory installed input lead and plug, With upgraded supply lead and plug

background image

INTRODUCTION

TRANSMIG 250i

Manual 0-5187

2-5 INTRODUCTION

2.09 Duty Cycle

The rated duty cycle of a Welding Power Source is a statement of the time it may be operated at its rated welding cur-

rent output without exceeding the temperature limits of the insulation of the component parts. To explain the 10 minute

duty cycle period the following example is used. Suppose a Welding Power Source is designed to operate at a 40%

duty cycle, 250 amperes at 26.5 volts. This means that it has been designed and built to provide the rated amperage

(250A) for 4 minutes, i.e. arc welding time, out of every 10 minute period (40% of 10 minutes is 4 minutes). During

the other 6 minutes of the 10 minute period the Welding Power Source must idle and be allowed to cool.

Art # A-10315

Duty Cycle (per

centage)

Safe

Operating

Region

0

25

50

75

80

100

125

150

225

250

30

50

70

90

40

60

20

10

100

0

Welding Current (amps)

Stick (MMAW)

TIG (GTAW)

MIG (GMAW)

175

200

With Factory Installed Input Lead and Plug

Figure 2-2: Transmig 250i Duty Cycle with Factory Fitted Supply Lead and Plug

Art # A-10316

Duty Cycle (per

centage)

Safe

Operating

Region

0

25

50

75

80

100

125

150

225

250

30

50

70

90

40

60

20

10

100

0

Welding Current Max (amps)

Stick (MMAW)

TIG (GTAW)

MIG (GMAW)

175

200

With Upgraded Supply Lead and Plug

Figure 2-3: Transmig 250i Duty Cycle with Upgraded Supply Lead and Plug