Transmig 250i installation/setup – Tweco 250i Transmig Inverter User Manual
Page 32
TRANSMIG 250i
INSTALLATION/SETUP
INSTALLATION/SETUP 3-14
Manual 0-5187
Function
Left Display
"Right Display
(Factory De-
fault Values)"
Limits
Comments
Down Slope
DOWN/SLPE
0.0 S
0.0 – 30 S
In “2T” (unlatched), the unit will enter down slope
mode as soon as the trigger switch is released (ie
if Down Slope is set to 5.0 S, the unit will ramp
down from the present welding current to zero
over 5 seconds).
In "4T" (latched), to enter down slope mode the
trigger switch must be held in for the selected
time period (ie press and release trigger switch to
commence welding, then press and hold trigger
switch again to enter down slope mode). Should
the trigger switch be released during the down
slope time, the output will cease immediately in
"4T" only.
Arc Hour Accu-
mulated Run-
time
HR
0.0
0.0 – 9999.9
Provides Arc On Hours that the power source has
welded. The number displayed is in hours and
read only. It will rollover to 0 once 10,000 hours
have been reached.
Restore Factory
Defaults
FACT/DFLT
NO
NO – YES
When YES is selected all the user adjustable val-
ues in this table (except Arc Hour Accumulated
Runtime) are reset to the Factory Default Values.
STICK Mode Advanced Features
ON OFF
0.0 - 2.0 S
75 - 200 %
Advanced Menu - STICK
Options or Range
Press Advanced Button
to Exit to Welding Mode
LOCL REMT
NO YES
0.0 - 9999.9
HOT- / START
HS / TIME
HS / AMPS
Advanced Menu - STICK
Mode
HR
Press Advanced Button
to Exit to Welding Mode
STCK / CNTL
FACT / DFLT
Left Knob Selection
Left Display: Where (2) items shown, e.g. HOT- / STRT, the display will alternate (flash) between the (2) items
Right Knob Selection
Left Display
Right Display
Art # A-10323
Figure 3-7: Stick Advanced Menu
Function
Left Display
Right Display
(Factory De-
fault Values)
Limits
Comments
Stick Operator
Controls
STCK/CNTL
LOCL
LOCL - REMT
LOCL = Local control of the Amps with the
machines controls
REMT = Remote control of the Amps with an
accessory device