APPENDIX

52

Manual 0-2023

APPENDIX IV: NECESSARY CONNECTIONS - RP-1 NOT

USED WITH CS-1 WITH OR WITHOUT GS-1, WT-1 OR CP-1

TB3-1

TB3-4

TB1-1

TB3-6

TB2-1

TB2-2

28

26

15

13

16

11

24

20

Pot High

Pot Low

Wiper

10k, 2 Watt Potentiometer Should Be
Used For Remote Current Control (See Note 4)

Start Downslope (Momentary Closure)
Active When Closed (See Note 2)

Start Sequence (Momentary Closure)
Active When Closed (See Note 1)

Chassis Ground

Not System Common

A-02451

Contactor Control (See Note 3)
Contactor ON/OFF Used To Control The Contactor.
When Open The Contactor Cannot Be Energized.

NOTES
1. Contacts Must Be Open Prior To Downslope Signal.

2. Downslope Signal Not Required If WT-1 Is Used.

3. Contacts Are Off The Same Double Pole Relay

4. Wire #11 Is System Common Not Chassis Ground.

Contactor Control (See Note 3)
Contactor ON/OFF Relay Resets Control Logic

Resets Control Logic