INSTALLATION PROCEDURES
12
Manual 0-2023
3. Connect plug (supplied) to the end of the input power
cord per the following:
a. Feed the free end of the input power cable through
the small section of the rubber plug housing.
b. Connect the ground lead to the green terminal on
the plug.
c. Connect the other two leads to the two terminals
on the plug.
d. Press the plug into the rubber housing until the
plastic disk is captured by the rubber housing.
e. Tighten cord grip to secure input cable.
B. Cable Connections
1. Connect RP1 Control pendant to the connector on the
end of the 20 foot (6.1 m) Remote Control Cable. Con-
nect the other end of the cable to the back of the Weld
Sequencer Enclosure marked REMOTE CONTROL.
REMOTE
CONTROL
CONSOLE/POWER SUPPLY
CONTROL
A-02406
Control Cable
Console/Power Supply
Control Cable
Figure 3-3 Weld Sequencer Enclosure Rear Panel
Connections
If a different remote control device is to used refer to
the Wiring Diagram supplied with the Weld Se-
quencer. The current control potentiometer must be
rated for 10k ohm at 2 watts.
Plasma Gas
Shield Gas
A-02407
Weld
Sequencer
Optional Remote
Control
Torch
Welding
Console
DC Power
Supply
Coolant Recirculator
Figure 3-4 WC100B Connections