Parameter Descriptions

3-129

Provides status of the profile/indexer. Bits 0-4 are a binary value.

Number of units traveled from the home position.

700

Profile Status

Range:

See figure 3.42

Default:

Read Only

Access:

2

Path: Pos/Spd Profile>ProfSetup/Status

See also:

Figure 3.42 – Pos/Spd Prof Sts

0

0

0

0

0

x

x

x

0

0

0

0

0

0

0

0

10

0

1

2

3

4

1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0

Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Step 10
Step 11
Step 12
Step 13
Step 14
Step 15
Step 16

0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0

0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0

0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0

0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1

5

6

7

8

9

11

12

13

14

15

1 =Enabled
0 =Disabled
x =Reserved

Bit #

Step

Current Pr

ofile

Pr

of Enab

led

Running

Holding

Homing

At P

osition

At Home

Complete

Vel Override

701

Units Traveled

Range:

-/+ 214748352.00 [0.01]

Default:

Read Only

Access:

2

Path: Pos/Spd Profile>ProfSetup/Status

See also: