B.2 application/installation considerations – Rockwell Automation VSM500 Integrated Drive/Motor User Manual
Page 82
B-2
Installing and Operating the VSM500 Integrated Drive/Motor, Version 3.0
•
Storage temperature range extended. The storage temperature rating has been
extended from 70°C to 85°C.
•
CE Mark. The unit now conforms to the EMC and LVD directives for CE. An optional
line filter is required.
•
CE Line Filter Option. Single- and three-phase line filters can be mounted
internally or are packaged for external mounting.
•
DeviceNet Communication Option. A DeviceNet Option Board, purchased
separately, is installed inside the unit. Refer to the DeviceNet Option board
instruction manual, D2-3463, for more information.
•
Drive Parameters Added. Drive display parameters and drive program parameters
can be viewed or changed through a DeviceNet connection. Refer to the DeviceNet
Communication Option Board instruction manual, D2-3463, for more information.
B.2 Application/Installation Considerations
Keep the following in mind if you are planning to upgrade your unit or are considering
additional options:
•
If you are replacing a Version 1.0 or 2.0 unit with a Version 3.0 unit, keep in mind
that:
•
The minimum speed has been reduced from 90 RPM (3 Hz) to 0 RPM (0 Hz).
•
The terminal block stop input must be present for local operator control units.
•
The DeviceNet communication option is not available for Version 1.0 or 2.0 units.
•
The CE filter option is compatible with any version of the VSM500 integrated
drive/motor; however, only Version 3.0 meets the CE requirement.
•
The short cover has been replaced by a tall cover.