Ppendix, Product features, B.1 new features in version 3.0 – Rockwell Automation VSM500 Integrated Drive/Motor User Manual
Page 81

Product Features
B-1
A
PPENDIX
B
Product Features
The following features are standard on every VSM500 unit:
•
Totally enclosed standard NEMA frame sizes with C-face and foot mounting. IEC
frames and flanges are available.
•
PWM (pulse-width modulated) drive section with a microprocessor-based V/Hz
regulator.
•
Design B inverter-duty motor section:
-
Class F non-hygroscopic insulation system resists heat, oil, and water.
-
Double-shielded bearings.
•
Four-character, seven-segment LED display to indicate speed, %load, and
diagnostic information.
•
0 to 10 VDC or 4 to 20 mA analog input for remote speed reference from a PLC or
process controller.
•
0 to 10 VDC analog output to provide remote speed or %load indication.
•
Seven selectable preset speeds.
•
Form A contact output to indicate drive running or drive faulted condition.
•
500 ms power dip ride-through time.
•
Protection features, including sensing for overtemperature, overcurrent, high DC
bus voltage, low DC bus voltage, and surge suppression.
•
Conduit cover can be rotated 180
°
to provide the appropriate display view in each
application.
•
User-selectable coast-to-rest (default) or ramp-to-rest (user option) stop.
•
User-selectable variable torque (default) or constant torque (user option) operation.
•
8 kHz carrier frequency for quiet operation.
•
Complies with UL 1995.
B.1 New Features in Version 3.0
•
Additional start mode selection. Local operator control units can be controlled
from either the operator controls or the terminal block.
•
Terminal block stop input. The terminal block stop input and local operator control
stop key are active for all start mode selections.
•
Zero speed operation. The minimum speed has been reduced from 90 RPM (3 Hz)
to zero.