beautypg.com

Rockwell Automation SP600 User Manual Version 3.0 User Manual

Page 130

background image

11-28

SP600 AC Drive User Manual

Sets the amount of compensation to drive output at motor FLA. If
parameter 61 (Autotune) = 3 (Calculate), changes made to this
parameter will not be accepted.

Important:

Parameters in the Slip Comp Group (121-123) are
used to enable and tune the slip compensation
regulator. To allow the slip compensation regulator to
control drive operation, Speed Mode (80) must be set
to 1 (Slip Comp).

Sets the response time of slip compensation. Increasing the value
will increase the slip compensation response.

Displays the present amount of slip adjustment being added to the
motor command frequency.

121

Slip RPM @ FLA

Range:

0.0 to 1200.0 RPM

Default:

Based on Motor NP RPM

Access:

2

Path: Speed Command>Slip Comp

See also:

61, 80, 122, 123

122

Slip Comp Gain

Range:

1.0 to 100.0 [0.1]

Default:

40.0

Access:

2

Path: Speed Command>Slip Comp

See also:

80, 121, 122

123

Slip RPM Meter

Range:

0.0 to 300.0 RPM

Default:

Read Only

Access:

2

Path: Speed Command>Slip Comp

See also: