4 ensuring program security – Rockwell Automation SP600 User Manual Version 3.0 User Manual
Page 100
10-6
SP600 AC Drive User Manual
10.4
Ensuring Program Security
Parameter values can be password-protected using the LCD OIM.
When the password is enabled, parameter values can be displayed.
However, if there is an attempt to change a parameter value, a
password pop-up box will appear on the OIM screen to prompt for
the user-defined password.
To set the write-protect password, select the Password icon from
the main menu. See figure 10.5. The password value can range
from 1 to 9999. A value of 0 disables the password (factory default).
When the password is enabled, the lock symbol on the screen
changes from
to
.
When you enter the password, you can adjust parameters until you
select Logout or return to the process display screen, which
re-activates the password. Refer to section B.8 in Appendix B for
information about the process display screen.
This option is not supported in the VS Utilities software.
If There is More Than One OIM Connected to the Drive
Important: Setting the write-protect password value to zero on one
OIM will disable the write-protect password on all
connected OIMs.
Setting the write-protect password in one OIM will not affect any
other OIM connected to the drive unless a write-protect password
!
ATTENTION: It is the user’s responsibility to determine how
to distribute the write-protect password. Reliance Electric is
not responsible for unauthorized access violations within the
user’s organization. Failure to observe this precaution could
result in bodily injury.
Figure 10.5 – Setting the Write-Protect Password
Auto
Stopped
Main Menu
Password
P0: SP600
Password:
Set Acc Lvl PW
Set Wrt Prot PW
Set Access Lvl
Set Wrt Prot PW:
0
New Code:
Increase/decrease value
Move placeholder
Accept value
Highlight option
Highlight Password icon
Monitor
Lang
>>