Slew enable, Slew limit, Master gear count 0 – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual
Page 98: Motor gear count 0, Master gear count 1, Motor gear count 1, Master gear count 2, Motor gear count 2, Master gear count 3
Publication 2098-RM001C-EN-P – August 2002
2-82
Programming Reference
261
Set
Analog Decel
Limit
UDINT
4
Cnts /
Sec
2
The deceleration limit used when the drive is in
Analog Velocity Input mode and Parameter 259,
Limit Analog Accel is set to 1 - Enable.
Range: 0 to 0x7fffffff
Default: 100000
262
Set
Slew Enable
USINT
1
Used to enable or disable the Gear Slew Rate.
0 - Disable (default)
1 - Enable
263
Set
Slew Limit
UDINT
4
Cnts /
Sec
2
Slew rate (acceleration/deceleration limit) used for
gearing.
Range: 0 to 0x7fffffff
Default: 100000
264
Set
Master Gear
Count 0
UINT
2
Cnts
Master encoder counts for preset gear ratio 0. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1
265
Set
Motor Gear
Count 0
INT
2
Cnts
Motor encoder counts for preset gear ratio 0. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1
266
Set
Master Gear
Count 1
UINT
2
Cnts
Master encoder counts for preset gear ratio 1. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1
267
Set
Motor Gear
Count 1
INT
2
Cnts
Motor encoder counts for preset gear ratio 1. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1
268
Set
Master Gear
Count 2
UINT
2
Cnts
Master encoder counts for preset gear ratio 2. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1
269
Set
Motor Gear
Count 2
INT
2
Cnts
Motor encoder counts for preset gear ratio 2. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count. This
value should be nonzero.
Range: -32767 to 32767
Default: 1
270
Set
Master Gear
Count 3
UINT
2
Cnts
Master encoder counts for preset gear ratio 3. The
preset gear ratio is defined by the ratio of the
Master Gear Count and the Motor Gear Count.
Range: 1 to 32767
Default: 1
Parameter Object,
Instances ID = 1- 996
Parameter
Instance
Access
Rule
Parameter
Name
Data
Type
Data Size
(Bytes)
Units /
Scale
Description