Speed window, Up to speed, Position window size – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual
Page 75: Position window time, Position compare 1 polarity, Position compare 1, Position compare 2 polarity, Position compare 2, R 49 (position compare 1 polarity, R 50 (position compare 1)
Publication 2098-RM001C-EN-P – August 2002
Programming Reference
2-59
45
Set
Speed Window
UDINT
4
Cnts /
Secs
A +/- range, or window, around the velocity
command. If the motor feedback velocity falls within
this range, the Speed Window flag will be (or
remain) set.
Range: 0 to 0x7fffffff
Default: 1000
46
Set
Up to Speed
UDINT
4
Cnts /
Secs
If the motor feedback velocity is greater than or
equal to this value, the Up to Speed flag will be (or
remain) set.
Range: 0 to 0x7fffffff
Default: 100000
47
Set
Position Window
Size
UDINT
4
Cnts
The maximum amount of position error which will
permit the In Position and the In Position Window
flags to be (or remain) set.
Range: 0 to 0x7fffffff
Default: 20
48
Set
Position Window
Time
USINT
1
mSec
The minimum length of time the position error must
be less than the Position Window Size value, for the
In Position and the In Position Window flags to be (or
remain) set.
Range: 1 to 255
Default: 20
49
Set
Position Compare
1 Polarity
USINT
1
Selects the type of comparison that will determine if
the Position Compare 1 flag should be set.
0 - Position > Position Compare 1 (default).
1 - Position <= Position Compare 1.
Note: The Position Compare 1 Polarity does not
operate unless the drive was previously homed.
50
Set
Position Compare
1
DINT
4
Cnts
The position that will be compared to the motor
(auxiliary) feedback position to determine if the
Position Compare 1 flag should be set.
Range: -0x7fffffff to 0x7fffffff
Default: 0
51
Set
Position Compare
2 Polarity
USINT
1
Selects the type of comparison that will determine if
the Position Compare 2 flag should be set.
0 - Position > Position Compare 2 (default).
1 - Position <= Position Compare 2.
Note: The Position Compare 2 Polarity does not
operate unless the drive was previously homed.
52
Set
Position Compare
2
DINT
4
Cnts
The position that will be compared to the motor
(auxiliary) feedback position to determine if the
Position Compare 2 flag should be set.
Range: -0x7fffffff to 0x7fffffff
Default: 0
Parameter Object,
Instances ID = 1- 996
Parameter
Instance
Access
Rule
Parameter
Name
Data
Type
Data Size
(Bytes)
Units /
Scale
Description