Publication 2098-RM001C-EN-P – August 2002
Programming Reference
2-91
360
and
370, 380, …,
970, 980, 990
Set
Index 0 Dwell
and
Index n Dwell
where n = 1-63
UINT
2
mSec
The amount of time the drive holds position before
continuing to the next index.
Range: 0 to 65535
Default: 0
361
and
371, 381, …,
971, 981, 991
Set
Index 0
Registration
Distance
and
Index n
Registration
Distance
where n = 1-63
UDINT
4
Cnts
For Registration index moves, specifies the relative
distance of travel after a registration digital input is
detected.
Range: 0 to 0x7fffffff
Default: 1000
362
and
372, 382, …,
972, 982,
992
Set
Index 0 Velocity
and
Index n Velocity
where n = 1-63
UDINT
4
Cnts /
Sec
The commanded velocity used when executing the
index.
Range: 0 to 0x7fffffff
Default: 100000
363
and
373, 383, …,
973, 983,
993
Set
Index 0 Accel
and
Index n Accel
where n = 1-63
UDINT
4
Cnts /
Sec
2
The acceleration rate used to change to higher
velocity during the index move.
Range: 0 to 0x7fffffff
Default: 100000
364
and
374, 384, …,
974, 984,
994
Set
Index 0 Decel
and
Index n Decel
where n = 1-63
UDINT
4
Cnts /
Sec
2
The deceleration rate used to change to a lower
velocity during the index move.
Range: 0 to 0x7fffffff
Default: 100000
365
and
375, 385, …,
975, 976,
995
Set
Index 0 Pointer
and
Index n Pointer
where n = 1-63
USINT
1
Specifies the next index move to execute if the Index
0 Terminate parameter is not set to 'Stop'.
Range: 0 to 63
Default: 0
366
and
376, 386, …,
976, 986,
996
Set
Index 0 Terminate
and
Index n Terminate
where n = 1-63
USINT
1
The drive's action when the index move has
completed.
0 - Stop
1 - Start Next Index immediately
2 - Wait for Start - 'Start Index' active transition
required to start next index.
3 - Index Without Stop - execute the next index
without stopping. The dwell time is ignored and a
'Start Index' is not required.
Parameter Object,
Instances ID = 1- 996
Parameter
Instance
Access
Rule
Parameter
Name
Data
Type
Data Size
(Bytes)
Units /
Scale
Description