Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual
Page 51
![background image](/manuals/580064/51/background.png)
Publication 2098-RM001C-EN-P – August 2002
Programming Reference
2-35
Assembly Object,
Instance ID = 14 - Input Assembly
Alternate 32 Bit Logic Status with Write Data Status Bits (replacing Position Limits Bits), and Feedback Data Value
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
1
Write Data
Busy/Ack
Write Data
Error
2
3
Reserved
Reserved
Reserved
Reserved
4
Feedback Data Value - Low Byte
5
Feedback Data Value - Low Middle Byte
6
Feedback Data Value - High Middle Byte
7
Feedback Data Value - High Byte
Assembly Object,
Instance ID = 15 - Input Assembly
Alternate 32 Bit Logic Status with Write Data Status Bits (replacing Position Limit Bits)
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
1
Write Data
Busy/Ack
Write Data
Error
2
3
Reserved
Reserved
Reserved
Reserved