beautypg.com

Positive soft position limit, Negative soft position limit, Positive decel distance – Rockwell Automation 2098-DSD-xxx Ultra3000 Digital Servo Drives with DeviceNet User Manual

Page 74: Negative decel distance, Zero speed limit, Ter 44, Zero speed limit se, R 44 - zero speed limit

background image

Publication 2098-RM001C-EN-P – August 2002

2-58

Programming Reference

40

Set

Positive Soft
Position Limit

DINT

4

Cnts

The absolute position that will cause a deceleration
to zero velocity when exceeded in the positive
direction.
Range: -0x7fffffff to 0x7fffffff
Default: 0x7fffffff

Note: This parameter instance is not available to
non-indexing drives. If invoked, a non-indexing drive
returns Reserved as the parameter name.

Note: The Positive Soft Position Limit does not
operate unless the drive was previously homed.

41

Set

Negative Soft
Position Limit

DINT

4

Cnts

The absolute positive that will cause a deceleration
to zero velocity when exceeded in the negative
direction.
Range: -0x7fffffff to 0x7fffffff
Default: -0x7fffffff (0x80000001)

Note: This parameter instance is not available to
non-indexing drives. If invoked, a non-indexing drive
returns Reserved as the parameter name.

Note: The Negative Soft Position Limit does not
operate unless the drive was previously homed.

42

Set

Positive Decel
Distance

DINT

4

Cnts

The distance that an axis will travel when an
overtravel limit has been reached in the positive
direction.
Range: 0 to 0x7fffffff
Default: 0

Note: This parameter instance is not available to
non-indexing drives. If invoked, a non-indexing drive
returns Reserved as the parameter name.

43

Set

Negative Decel
Distance

DINT

4

Cnts

The distance that an axis will travel when an
overtravel limit has been reached in the negative
direction.
Range: 0 to 0x7fffffff
Default: 0

Note: This parameter instance is not available to
non-indexing drives. If invoked, a non-indexing drive
returns Reserved as the parameter name.

44

Set

Zero Speed Limit

UDINT

4

Cnts /
Sec

A +/- range, or window, around zero velocity. If the
motor feedback velocity falls within this range, the
Zero Speed flag will be (or remain) set.
Range: 0 to 0x7fffffff
Default: 500

Parameter Object,
Instances ID = 1- 996

Parameter
Instance

Access
Rule

Parameter
Name

Data
Type

Data Size
(Bytes)

Units /
Scale

Description