70 Application Examples

Example DNI Configuration
Parameters

All example ladder logic programs in this section use the following
DNI configuration.

Parameter Number

Description

Range

Default Value

For this Example,

ENTER

Series A

Series B

4

1

Input Size

Series A: 1…16

Series B: 1…32

1 word

4 words

Not
Applicable

2

Input Split Point

1…32

1 word

4 words

5

3

Input Type

Bit or Integer File

Integer File

Integer File

6

4

Input Data File

3…254

7

7

7

5

Input Word Offset

0…254

0

90

8

6

Output Size

Series A: 1…16

Series B: 1…32

1 word

4 words

Not
Applicable

7

Output Split Point

1…32

1 word

4 words

9

8

Output Type

Bit or Integer File

Integer File

Integer File

10

9

Output Data File

3…254

7

7

11

10

Output Word Offset

0…254

1

95

14

11

DF1 Device

0…3:

0: Other

1: PLC

2: SLC/ Other MicroLogix

3: MicroLogix 1000

3 = MicroLogix 1000

3 = MicroLogix 1000

3

12

DNI Series A:

Data Enable

DNI Series B:

I/O Scan Enable

(Polling Enable)

0 or 1

Disabled (0)

Enabled (1)

12

13

DF1 Heartbeat

Series A: 2…10

Series B: 1…10

2

2

13

14

Data Scan Delay

(Polling Delay)

20…3000 ms

50 ms

100 ms

2

15

Message Timeout

0…2500 ms

0 ms

0 ms

Not
Applicable

16

DF1 Substitute
Address

0…64

64 = Disabled

64 = Disabled

15

17

DF1 Autobaud

Disabled (0) or Enabled (1) Enabled (1)

Enabled (1)