Chapter 3

Using Add-On Instructions

The following procedures demonstrate how to use the Jog parameter of the Motor

Starter Add-On Instructions.

Using the Jog command in ladder diagram

The first rung sets the Jog bit of Motor_Starter_LD = Jog_PB.

Use another instruction, an assignment, or an expression to read or write to the tag name of the parameter. Use this format for the tag name of the parameter.
Add_On_Tag.Parameter

Where

Is

Add_On_Tag

An instance tag defined by the Add On data type.

Parameter

Name of the parameter.