Install the RSIPCMK Driver for the Windows 95/98 Operating Systems 3-15

Publication 1784-UM519C-EN-P - September 2006

9. Verify that there are no resources conflicts listed in the Conflicting Device

list.

10. Verify that an interrupt has been assigned to the PCMK card.

An interrupt must be assigned. You may have to disable another device,
such as an unused communications or parallel port, to make an interrupt
available for the PCMK card.

• If there are conflicts, you may need to alter the settings of devices involved

in the conflict to get the PCMK card to function properly. Try deselecting the
Use automatic settings box and then changing the interrupt or
memory resources. This procedure works only in the Windows 95 operating
system.

• If there are no conflicts, continue with the following steps.

11. Return to the Device Manager and scroll through the list to find PCMCIA

socket.

12. Double-click PCMCIA socket to expand it.

13. Click the PCMCIA controller used by your system.