Dashboard Overview
You can use the dashboard to monitor switch status and performance.
The Dashboard window is similar to the Monitor > Trends window. The
Dashboard window displays the instantaneous status while the Trends window
displays the historical status. By using them together, you can gather the detailed
conditions of the switch and its ports. For information about the Trends window,
see
Front Panel View and Status Indicators
The Front Panel view is a graphical display of the front panels of the base switch
and attached switch expansion modules.
The switch components on the Front Panel view are color-coded by status. The
colors help you to quickly see if a fault or an error condition exists. The
system-level status indicators and port-level status indicators shown on the Front
Panel view match those on the physical switch.
Table 5 - System-level Status Indicators
Indicator
Status
Description
EIP Mod
The EIP Mod status indicator shows the status of the switch.
Off
Power to the switch is off or is not properly connected.
Solid green
The switch is operating properly.
Blinking green
The switch is not configured. For example, the switch does not have an IP address configured.
Blinking red
The switch has detected a recoverable system fault. Use the System Log to see more details about the problem.
See
View System Log Messages on page 132
.
Solid red
The switch has detected a non-recoverable system. Use the System Log to see more details about the problem.
See
View System Log Messages on page 132
.
Blinking green and red
The switch is running its power-on self-test (POST).