4. Push the upper and lower module latches in to secure the module to the
switch.
5. If you are installing a second module, repeat steps
4
, but secure the
second module to the right side of the first module.
Mount the Switch
on a DIN Rail
Follow these steps to mount the switch on a DIN rail.
1. Insert a sharp tool, such as a screwdriver, in the space next to the tab, push
gently to release the catch, then turn the screwdriver to push the tab out.
IMPORTANT
You cannot install an expansion module to the right of the
1783-MX08F or 1783-MX08S fiber expansion module.
31781-M
WARNING: When using DIN rail mounting, additional grounding is also
accomplished through the DIN rail to chassis ground. Use zinc plated
yellow-chromate steel DIN rail to assist in proper grounding. The use of other
DIN rail materials (for example, aluminum or plastic)) that can corrode, oxidize,
or are poor conductors, can impede proper grounding. Secure DIN rail to
mounting surface approximately every 200 mm (7.8 in.) using end-anchors
appropriately and using a washer plate along the entire length of the DIN rail.